Posts: 140
I have the same set (ct16) and in my case the first symptom was the lost of converging adjustments in one of the color(green) hv was check and was detected at 17 thousand top, a few days later was at 15 and the poof. chassis was removed and all the voltages coming out of electrolytic tested ok. the high voltage transformer burned. it was replaced with a nos and all problems were solved.