Quote:
Originally Posted by bgadow View Post
Let me know what you're looking for and I'll see what I can find.
I'm looking for the following. 2500pF @ 30KV, 1200pF @ 15KV, and 1000pF @ 10KV. I'm probably going to get a 2000pF 40KV for the first one since I feel 30KV is under rated for a 25KV line that can do over 30 if the regulation fails, and Bob G has had success with that value...I think I can find the 1000 on mouser, but I'm not sure what to do about the 1200...it seems Murata does not make that value of door knob anymore according to the datasheet for that part family. If I can I'd like to go up 5-10KV on all the door knobs I order to ensure they last as long as I live (especially since they are getting discontinued). Also according to the datasheet the threaded ends only project about 1mm so I'm going to have to come up with something with the parts available at the local hardware store to match the 1" terminal projection of the originals.

If you rather we discuss this privately send me an email. My PM box is full.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!