While you're at it change the HV rect filament winding...That much chew is likely to arc through. Better to do that now while it is easy to get at.
Quote:
Originally Posted by Crist Rigott
Today I cleaned and checked the tubes. There were 4 that were bad out of the 25 tubes. One just checked into the green. Those five will be replaced.
I then reinstalled the CRT wiring. I placed clear heat shrink tubing around each wire where it went through the chassis for protection.
I then redid the 2 terminal strips on the top of the chassis. One included the .25A fuse.
I then turned my attention to the Flyback and 1B3GT connector. I replaced the 3 220K 2W resistors with 3 220K 3W resistors. After looking over the Flyback a little closer, it looks like the mice tried to make a meal out of it! They also nibbled on the filament wiring to the 1B3GT connector.
I'm re-coating the Flyback windings with some Super Corona dope as I type. A few more coats and it will be ready to put back into the chassis.
|