IF capacitors that could be in question:
  • C22 and C23 are original and untouched
  • C18, C19, C24 previously measured good after lifting a lead
  • C13, C14 replaced film capacitors, re-measured good in circuit 12/27
  • C16, C20, C21 all measured 20% low, replaced today and measured good in circuit 12/27
  • No other IF capacitors replaced

Doubled checked C1 and C2 test points on underside, all is correct

Maybe an issue: I retested R52 which is a 5% (gold band) 180 ohm that in and out of circuit measures 219 which is 22% high. I will replace, note I only have metal film resistors which some argue against using in the IF circuit.