View Single Post
  #4  
Old 04-29-2014, 03:56 PM
powerking powerking is offline
VideoKarma Member
 
Join Date: Mar 2014
Location: New Hampshire, U.S.A.
Posts: 126
I would bet that the Heathkit C-2/C-3 circuit design is very close to the Solar CB/CC one(s) or even copied directly (since Solar, Inc went out of business in 1945 or so). My CB-1-60 also used 2 8uF caps for the +500VDC supply in the leakage resistor divider network. I would bet that using a 250V cap to replace them is a bad idea; perhaps measure the voltage across them and make sure it not 500V! For my CB-1-60 restore, I have 2-22uF 400V caps in series with 330K-ohm (voltage balance) restistors across them. These old testers are all similar designs (not too much to a Wien bridge circuit).

Tom (PK)

Last edited by powerking; 04-29-2014 at 04:05 PM.