View Single Post
  #26  
Old 02-06-2023, 11:05 PM
BeamT BeamT is offline
VideoKarma Member
 
Join Date: Sep 2007
Location: Lincoln, NE
Posts: 18
It is a feed thru, its located in the bracket that is immediately to the side of the HOT socket. one end is connected to the yellow wire. It looks like a resister with a collar around it.

Not sure how you feel about your past steps but this might be a good time to regroup and repeat and verify some of your work. Zeno's advice is quite sound.

Can you post a picture of the 3 safety caps you replaced?

Have you checked the damper diode?

You can check the feed thru cap with an ohmmeter but that does not rule it out as a problem. It may not be shorted with a DC voltage present but if you put the screws back into the HOT, the horiz circuit will start and the AC voltage there is quite high. From the HOT socket, collector pin, what sort of resistance to ground are you seeing?
__________________
Todd
Reply With Quote