View Single Post
  #64  
Old 11-19-2019, 09:53 PM
Dubis7's Avatar
Dubis7 Dubis7 is offline
Alchemizes cash to tubes
 
Join Date: Nov 2014
Location: Leesburg, VA.
Posts: 397
Okay,

C2D has been replaced. I'm not seeing any change.

For good measure I also swapped in a new vertical output tube. Also nothing.

I measured the ohms on R5. It peaks just around 2K, which I belive is what it's supposed to be. When I measure the voltage output coming off of R5, which is listed at 15V in the schematic, I'm seeing it maxing around 22-25V and brushing at 15V at the lowest.

Any suggestions for what to check next?
__________________
To keep your tubes running smoothly, make sure to dust underneath the glass as well.
Reply With Quote