Thread
:
Sencore VA62 Blows Line Fuse
View Single Post
#
2
12-03-2016, 07:33 PM
Electronic M
M is for Memory
Join Date: Jan 2011
Location: Pewaukee/Delafield Wi
Posts: 14,787
Check for shorts at the plug with a DMM in ohms mode. If resistance is reasonable check the lytics on the rectified secondary (s)...If any of those lytics are shorted or very leaky they could pop the fuse.
__________________
Tom C.
Zenith: The quality stays in EVEN after the name falls off!
What I want. -->
http://www.videokarma.org/showpost.p...62&postcount=4
Electronic M
View Public Profile
Find all posts by Electronic M