Quote:
Originally Posted by bandersen View Post
Is one of the caps in the vertical ceramic ? It's capacitance will change when high voltage is applied causing problems. That's why you should use film or a ceramic cap much larger than what is called for. Swap the two caps around and see if the problem changes.
I thought about switching them around. I did put several red film caps in series and parallel to make .005 but that didn't do anything to help. I have the one white tubular on one side and 2 ceramic 2kv caps on the other side and are equal to the NF of the other but if the capacitance changes with hv then I guess it won't work.