View Single Post
  #4  
Old 01-02-2016, 06:37 PM
zeno's Avatar
zeno zeno is offline
VideoKarma Member
 
Join Date: Mar 2013
Location: New Hampshire
Posts: 4,693
http://www.ebay.com/itm/Zenith-Repla...EAAOSwjVVVuOgz

I found the other lot but no triac kit, just cables. The triac is
the MOST likely problem.

Big IIRC's here...... When these came in with either triac or
isolator bad we did the following to prevent call backs.
Changed triac, isolator, manual on/off button & remote-manual
switch. The switches would go int & cause int on/off by itself
problems. List of symptoms, you can get one or more:

Dead set
Stuck on
Int off
Int on
Int breaker tripping
Int severe pix breaking up
Int turn off by itself
Int turn on by itself
Probably more but its been 35 yrs !!!

BTW this circuit is used in the flat chassis AND the CC2 upright
remote sets E & F line. G line switched to a normal on/off relay.

73 Zeno