Thread: Porta color
View Single Post
  #48  
Old 12-23-2017, 04:12 AM
1911nutjob 1911nutjob is offline
VideoKarma Member
 
Join Date: May 2009
Location: Nw Indiana
Posts: 24
Quote:
Originally Posted by zeno View Post
Yes. So the customer cuts the prongs to fit...........
All kidding aside we changed all modified cords as a CYA step. They
are redundant as everything is plastic. No effect on operating the TV.
BTW some chassii are hot either way......

As for doing a B&W first just get your set to be as good a B&W first
then worry about color.
Series string sets to find open filament do this.
Meter on AC, ground one lead. Go along pin 1 & 12 til you find one
with no AC on one pin.
BTW you will measure 120VAC all along the string. That will not match
the data. Its because with the open there is no current so no voltage
drop along the string.

73 Zeno
LFOD !
Good call, appreciate the tech info and won’t waste my time with b&w. I’m gonna set up a Flickr account shortly so I can get some pics going for you guys.
Reply With Quote