Chassis 22H20 (H2227R). Works fine EXCEPT video flashes on and
off at about 1 second intervals. Tubes check out fine, have full screen with some retrace so I figure a cap is charging up and dumping its voltage; an electrolytic, perhaps?
Outside of trying to meter these voltage changes with the set
on, any suggestions as to where to start?

Thanks!
Reply With Quote
  #2  
Old 07-19-2002, 05:44 PM
Rob Rob is offline
Banned
 
Join Date: Jun 2002
Posts: 776
It's breathing!

Michael,

I had a similar problem with my 1947 Admiral 30A13 chassis. It went away when I stopped trying to use rabbit ears in a fringe area and put a good strong signal from a VCR into the set. Your problem may be that the AGC circuit has an open time constant electrolytic capacitor and is motorboating due to slow time constant positive feedback. Without looking at a schematic the AGC is generally a common bias line that supplies the grids of at least the IF tubes, and sometimes the RF amp in te tuner as well from an AGC detector like a 6AL5. The grid resistors will not go to chassis ground in this case, but to a bus bypassed at each tube feed by a small disc capacitor.

Rob
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 04:49 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.