  #12  
Old 10-01-2018, 12:19 AM
Sparky's Avatar
Sparky Sparky is offline
VideoKarma Member
 
Join Date: Feb 2005
Location: Central FL
Posts: 54
ALL caps are suspect after another remote session today. I hope you have a good cap checker that has leakage & rated voltage like the Sencore. Check at the linearity coil. Brown caps were all leaking at 200V & 600V ratings. Try not to use any yellow caps in the AC current circuits. HV bypass is OK but not current. I know, as see you are using Orange Drops, but I am speaking to the uninformed.
BTW same tangled mess in the pot.
I guess your yoke is OK or is that another one?
Keep us posted!


Quote:
Originally Posted by Tellyrescue View Post
Good tip on the disc, never though to check it.
I had to replace the horizontal width pot as the fine wire was all tangled up inside and believe it shorted out taking the resistor on the back of it and the horizontal winding on the original yoke with it.
I also replaced the two caps in that area. I now have HV but it needs to be reduced.

Last edited by Sparky; 10-01-2018 at 09:47 PM.
Reply With Quote
 



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 09:08 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.