Videokarma.org

Go Back   Videokarma.org TV - Video - Vintage Television & Radio Forums > Early Color Television

We appreciate your help

in keeping this site going.
Reply
 
Thread Tools Display Modes
  #1  
Old 01-19-2018, 01:15 PM
etype2's Avatar
etype2 etype2 is offline
VideoKarma Member
 
Join Date: Mar 2010
Location: Valley of the Sun, formerly Silicon Valley, formerly Packer Land.
Posts: 1,494
Very good advise from Bob. It astounds me how any of the components can survive literally mm’s from heat producing tubes. A recipe for failure. We also added a fan in our 21CT55 by cutting off the “chimney”. The hole is already cut in that location. Added a switch to shut it off if needed. As an added precaution, the power is regulated with a Furman power conditioner.

We had a failure after several months of operation. Suddenly lost convergence, focus and the picture shrunk. “Oh no, the flyback!” We traced the problem to an open resistor buried under the damper tube.

The High Voltage was reduced to 10 KV with this failure. It now adjusts nicely from 18 KV to 21 KV as it should. (Edit: Mike saw 25 KV, set it to 21.5 KV) The resistor was an original (made by International Rectifier) special film type, 3.4 Megohm 3 watt. It was replaced with QTY 2 (in series) OHMITE 2.2 Megohm 2 Watt film type which now makes the new resistor a 4 watt unit which is a 25% upgrade for power dissipation.

Did you check the serial number stamped on the wood pull out under the pencil box? Wishing you continued success in the restoration.

A few photos of the bad boy resistor, replacement and fan:









__________________

Last edited by etype2; 03-29-2018 at 01:34 PM. Reason: Typo discovered
Reply With Quote
  #2  
Old 01-31-2018, 09:12 AM
miniman82's Avatar
miniman82 miniman82 is offline
First Light: 1952-2011
 
Join Date: Jun 2009
Location: Great Mills, MD
Posts: 4,159
Quote:
Originally Posted by etype2 View Post
The High Voltage was reduced to 10 KV with this failure. It now adjusts nicely from 18 KV to 21 KV as it should.
Once again, the HV specification for the 21-CT-55 is NOT 21kv. It is 25, please stop spreading misinformation. If you want to run your own set that way, that is your business. Don’t misquote service literature to others.
__________________
Evolution...
Reply With Quote
  #3  
Old 03-29-2018, 12:08 PM
benman94's Avatar
benman94 benman94 is offline
Resident Lunatic
 
Join Date: Jun 2011
Location: Detroit, MI
Posts: 1,190
Quote:
Originally Posted by miniman82 View Post
Once again, the HV specification for the 21-CT-55 is NOT 21kv. It is 25, please stop spreading misinformation. If you want to run your own set that way, that is your business. Don’t misquote service literature to others.
Amen.
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 02:45 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.