Question UPS RPT-800A REPOTEC cONNECTING

For dumb UPSes (such as RPT-800A REPOTEC) using voltage signalling, if you are going to build your own cable, we recommend to make the cable designed by the apcupsd team as follows:hi
my ups hawe pinout 5`2`4`6`7 db9 - its slight diferent from above sheme
https://networkupstools.org/cables.html#_tripp_lite
AND soft-app searhcing help me for non tx-rx com port ups soft

5+2 Shutdown load
5+4+8 Cable power (must be present for cable to have valid reading)
5+6 On line (no power failure) (opposite of OB - on battery)
5+7 Low battery
https://www.cyberpowersystems.com/products/software/
Quote:
Example Application
Supply 12VDC to the COMMON contact and connect LEDs to the DB-9
port pins 1, 2 and 6 to 9. Connect a push button to COMMON (Pin5) and

REMOTE SHUTDOWN (Pin4). Pressing the button for at least 5 seconds
will shutdown the UPS when it is on battery.
Note: When the UPS is on battery, the REMOTE SHUTDOWN input (Pin4
& Pin3) accepts at least 5 seconds of high level signal (+12VDC) to perform
the UPS shutdown. UPS output power will turn off after 120 seconds.
The default communication speed for all UPSs is 1200 baud.
For some optional cards, the communication speed could by 9600 baud.
Attached Images
File Type: jpg CAM00354[1].jpg (60.8 KB, 8 views)
File Type: jpg CAM00355[1].jpg (53.6 KB, 12 views)
File Type: jpg CAM00356[1].jpg (39.3 KB, 9 views)
__________________
hi
i am
Visual
http://www.videokarma.org/member.php?u=71610

Last edited by svhs; 11-04-2021 at 05:49 AM.
Reply With Quote
  #2  
Old 10-30-2021, 01:48 AM
svhs's Avatar
svhs svhs is offline
DIGITRON
 
Join Date: Jan 2019
Location: MULTIPLEX TV SOUND CATV;AIR;MTS;PCM;XDS-cc;vps;pdc;txt
Posts: 174
Minuteman UPS pinout

1-5
2-4
3-2
4-3
6-9
7-8
M-F

https://www.hobby-hour.com/electroni...calculator.php
NAME


The essence of a UPS definition in this driver is how it uses the serial lines that are available. These are the abbreviations you will see below:

OL

On line (no power failure) (opposite of OB - on battery)
LB

Low battery
SD

Shutdown load
CP

Cable power (must be present for cable to have valid reading)
CTS

Clear to Send. Received from the UPS.
RTS

Ready to Send. Sent by the PC.
DCD

Data Carrier Detect. Received from the UPS.
RNG

Ring indicate. Received from the UPS.
DTR

Data Terminal Ready. Sent by the PC.
ST

Send a BREAK on the transmit data line

A "-" in front of a signal name (like -RNG) means that the indicated condition is signaled with an active low signal. For example, [LB=-RNG] means the battery is low when the ring indicate line goes low, and that the battery is OK when that line is held high.
RPT Repoteck RPT-800A/RPT-162A

[CP=DTR+RTS] [OL=DCD] [LB=-CTS] [SD=ST]


genericups - Driver for contact-closure UPS equipment
NOTE

This man page only documents the specific features of the genericups driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE

This driver supports hardware from many different manufacturers as it only uses the very simplest of signaling schemes. Contact closure refers to a kind of interface where basic high/low signals are provided to indicate status. This kind of UPS can only report line power and battery status.

This means that you will only get the essentials in ups.status: OL, OB, and LB. Anything else requires a smarter UPS.
CABLING

Cabling is different for every kind of UPS. See the table below for information on what is known to work with a given UPS type.
__________________
hi
i am
Visual
http://www.videokarma.org/member.php?u=71610

Last edited by svhs; 11-07-2021 at 03:08 AM. Reason: Minuteman UPS pinout
Reply With Quote
  #3  
Old 11-04-2021, 07:47 AM
svhs's Avatar
svhs svhs is offline
DIGITRON
 
Join Date: Jan 2019
Location: MULTIPLEX TV SOUND CATV;AIR;MTS;PCM;XDS-cc;vps;pdc;txt
Posts: 174
Pin# Function Explanation I/O 2 Power Fail-normally open status, will become closed during active OUTPUT 4 Reference GND for pin2,
5 OUTPUT 5 Battery Low- normally open status, will become closed during active
OUTPUT 6 Remote shutdown UPS-keep this pin at high voltage(+5V~+12V) 500ms to shutdown UPS.

Activates at battery mode INPUT 7 Reference GND for pin6 INPUT


__________________
hi
i am
Visual
http://www.videokarma.org/member.php?u=71610

Last edited by svhs; 11-04-2021 at 09:17 AM.
Reply With Quote
  #4  
Old 11-04-2021, 10:04 AM
svhs's Avatar
svhs svhs is offline
DIGITRON
 
Join Date: Jan 2019
Location: MULTIPLEX TV SOUND CATV;AIR;MTS;PCM;XDS-cc;vps;pdc;txt
Posts: 174
Cool RUPS 2000 for UPS Monitoring

Sendon UPS-500 dumb cable pinouthttps://infopedia.su/21xa7e7.htmlhttps://shopee.vn/B%E1%BB%98-L%C6%AF...148.7143998622RUPS 2000 software has been developed for Uninterruptible Power Supplies (UPS) following the Dry Contact (DB9) communication protocol. It monitors the status of the UPS, shuts down the system before the UPS is exhausted and can remotely observe the UPS via the Internet (enabling users to manage their system more effectively). Upon AC failure or UPS battery low, RUPS takes all necessary actions without intervention from the system administrator. In addition to automatic file saving and system shut-down functions, RUPS can also send warning messages via pager, e-mail etc., thereby preventing file damage if power is suddenly turned off.
RUPS may be configured to start at system power-up, even if a user has not logged on. It also supports other user-added international language extensions. Nowadays, information is more and more important whether it be on personal computers or servers. In this context automatic power supply monitoring is essential to the effective deployment of a UPS. In offering comprehensive monitoring and control features RUPS provides the best possible UPS support available.
http://www.megatec.com.tw/Product_list.htm#RUPS
Attached Images
File Type: jpg RPS320ENU.pdf.jpg (62.5 KB, 45 views)
__________________
hi
i am
Visual
http://www.videokarma.org/member.php?u=71610

Last edited by svhs; 11-04-2021 at 10:57 AM.
Reply With Quote
  #5  
Old 11-04-2021, 11:03 AM
svhs's Avatar
svhs svhs is offline
DIGITRON
 
Join Date: Jan 2019
Location: MULTIPLEX TV SOUND CATV;AIR;MTS;PCM;XDS-cc;vps;pdc;txt
Posts: 174
Cool

WARNING : There is an electronic circuit inside the RUPS 2000 cable. Do not use this cable to connect with any devices other than a suitable UPS. Permanent damage may be caused if used in an inappropriate manner.Dumb Interface

Это стаpый и пpимитивный тип интеpфейса, пpедоставляющий лишь самую минимальную инфоpмацию о состоянии UPS. Он имеет тpи сигнальных линии:

· "AC Failure": сигнал от UPS к упpавляющему обоpудованию. Сообщает о пеpеходе UPS на батаpейное питание;

· "Battery Low": сигнал от UPS к упpавляющему обоpудованию. Сообщает о том, что батаpея достигла кpитического уpовня pазpяда и в скоpом вpемени не сможет обеспечить pезеpвного питания;

· "Shutdown UPS": сигнал от упpавляющего обоpудования к UPS. Подача напpяжения 6..12V на эту линию вызывает отключение инвеpтоpа и обесточивание нагpузки. Чтобы избежать случайных отключений, UPS обычно pеагиpует на этот сигнал только пpи условии удеpжания его в активном состоянии дольше 1..4 секунд и только во вpемя pаботы от батаpей.

Логика pаботы пpогpаммы-монитоpа, следящей за UPS чеpез Dumb Interface, достаточно пpоста. Пpи пеpеходе сигнала "AC Failure" в активное состояние она может запустить таймеp, и если по истечении заданного таймаута этот сигнал все еще активен, выполнить закpытие всех задач и завеpшить pаботу опеpационной системы. Дpугой ваpиант действий - ничего не пpедпpинимать до тех поp, пока не станет активным сигнал "Battery Low", после чего без пpомедления выполнить завеpшение pаботы опеpационной системы. Возможны также некие комбинации из этих двух методов. После завеpшения pаботы системы пpогpамма-монитоp может установить в активное состояние сигнал "Shutdown", чтобы выключить UPS. К сожалению, после отключения по этому сигналу у большинства UPS'ов для восстановления pаботоспособности тpебуется pучное вмешательство опеpатоpа - выключить его и снова включить. Автоматическое включение в этом случае не пpоисходит, т.к. батаpея UPS находится в pазpяженном состоянии и, веpоятно, не сможет обеспечить pезеpвное питание с момента начала загpузки системы и до момента активизации пpогpаммы-монитоpа, что в случае повтоpения пеpебоев с подачей электpоэнеpгии пpиведет к аваpийному отключению системы и возможной потеpе данных. Истоpически сложилось так, что pанние модели UPS, оснащенные Dumb Interface, тpебовали для pаботы с ним специальную плату - UPS Monitor Board (упоминания о ней можно встpетить, напpимеp, в Novell Netware 3.1x - входящий в ее состав модуль UPS.NLM pассчитан на pаботу именно с такой платой). В связи с этим интеpфейс не обеспечивает никаких опpеделенных логических уpовней на своем выходе и пpедставляет собой лишь набоp ключей, замыкающих сигнальный пpовод с общим. О необходимых смещениях для фоpмиpования логических сигналов, соответствующих, напpимеp, уpовням RS-232C, вы должны позаботиться сами (как пpавило, для этого в pаспайке соединительного кабеля используются pезистоpы, на котоpые подается высокий уpовень от сигнала RTS или DTR RS-232C). UPS'ы, Dumb Interface котоpых сам обеспечивает уpовни RS-232C (APC Back-UPS, напpимеp) - скоpее, исключение из общего пpавила.

В очень стаpых моделях, по слухам, в качестве ключей пpименялись обычные геpконовые pеле (отсюда и название - Contact Closure Type). В настоящее вpемя обычно используются тpанзистоpные оптpоны (чаще всего - шиpоко pаспpостpаненные 4N35), обеспечивающие надежную гальваническую pазвязку интеpфейса от внутpенней схемы UPS, либо специализиpованные микpосхемы. Однако в некотоpых дешевых моделях (напpимеp, MinuteMan A-420) вместо оптpонов в ключах стоят обычные биполяpные тpанзистоpы.
__________________
hi
i am
Visual
http://www.videokarma.org/member.php?u=71610

Last edited by svhs; 11-04-2021 at 11:49 AM.
Reply With Quote
Audiokarma
  #6  
Old 11-11-2021, 10:19 PM
svhs's Avatar
svhs svhs is offline
DIGITRON
 
Join Date: Jan 2019
Location: MULTIPLEX TV SOUND CATV;AIR;MTS;PCM;XDS-cc;vps;pdc;txt
Posts: 174
Exclamation Serial Ports Connector

ITS A LIE--WRONG PINOUT------------
Attached Images
File Type: png 7345v1.1.pdf.png (95.8 KB, 36 views)
File Type: png p55tv.pdf.png (41.8 KB, 35 views)
__________________
hi
i am
Visual
http://www.videokarma.org/member.php?u=71610

Last edited by svhs; 04-23-2022 at 12:39 PM.
Reply With Quote
  #7  
Old 04-23-2022, 12:35 PM
svhs's Avatar
svhs svhs is offline
DIGITRON
 
Join Date: Jan 2019
Location: MULTIPLEX TV SOUND CATV;AIR;MTS;PCM;XDS-cc;vps;pdc;txt
Posts: 174
13579
2468
__________________
hi
i am
Visual
http://www.videokarma.org/member.php?u=71610
Reply With Quote
Reply



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 09:06 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.