#1
|
||||
|
||||
The set is covered in Sams 1472-1
Measure the CRT pins 2, 6, 11, 4, 5, & 13 for VDC. Be sure your meter goes to at least 800V. Next the 3 G-2 controls are on the CRT socket. Turn one up all the way & see what you get on the screen. Then put it back & report findings. Zeno |
#2
|
|||
|
|||
Quote:
So then the 3 Variable Rheostats on the CRT Socket board marked as the Red, Green and Blue Screen Adjustments are the G2 adjustments on this TV? |
#3
|
||||
|
||||
Yes they are the G-2 controls. Watch the crack, it may have traveled....
Zeno |
#4
|
|||
|
|||
Quote:
|
|
|