View Single Post
  #3  
Old 04-16-2007, 09:10 PM
rj26220 rj26220 is offline
AK Member
 
Join Date: Mar 2007
Posts: 6
Ok

Hello,
Compucat thank you for the response. I have changed quite a few caps and resistors in other parts of the set and replaced the selenium rectifiers with diodes. The horz. osc. output caps. have been changed and it's output seems ok. The parts for the HV section (HV osc. and HV rectifier) have been changed or are ok. I tried to sub the 1b3 with a 1b3/1g3 but discovered, with the lights out, that with the 1g3 the HV section was squegging as I could see the 1g3 filament glowing in tune with the squegging!!!! I'm trying to get another 1b3 just
to see if there's a difference. I know I'm overlooking something but not sure what.

Rich
Reply With Quote