I know what you mean , I have a General electric like this exept it's the horizontal . and it is enough to drive you nuts it has had new caps ect. still not working .
It might be in the remote circuit .
im looking at a schematic is for a Canadian Zenith (19B20 , Q) Just using it as a reference . And the power supply is fairly simple . if it's like this one , it should be developing + 265v at the 80 MFD filter this is the B+ voltage
this voltage goes to the plate on the damper , after going through a spook coil assembly . This would cause me to think that the power supply is good as well , however this might be enough to run the horizontal but not the vert oscillator at full capacity check your voltage on your chassis .
does your set have ,
6CG7 VERT OSC .
6CK4 VERT OUT . ? that's what is on this schematic
is the HUM , a 60 cycle hum or does it's frequencey change when moving the vertical controls ? Im begining to think it might be a bias voltage that is low or a weak power resistor somwhere in there .
Do you have schematics for your Zenith ?
eventually it will run .