The area to stay clear of is using ceramic caps to replace the coupling caps used at the CRT deflection plates of electostatically-deflected sets (7JP4 types). There are documented cases of scanning nonlinearities that occurred when ceramic caps were used as replacements. This would indicate not using them as audio coupling caps as well.
In RF coupling and bypass applications they are fine, in fact very reliable.
|