Quote:
Originally Posted by Zenith26kc20 View Post
It seems to me that Zenith put the plate connection on the inside part of the winding. This has 1200 volts signal (vertical) and 390 volts DC. When mine failed, it appears that the puncture in insulation would cause the arcing that I noticed, but no sign of distress with the 6HE5 pulled. It also makes sense with JK unhooked....
The engineer at TMI said the insulation may only be 3 mils thick (the nearly transparent tape). No wonder it may get into trouble....
Maybe one should mount the transformer with its frame and core insulated from the chassis ground. Thus making life on the insulation a little easier. Though the transformer frame would become a shock hazard, but once the TV is back together that shouldn't be a big issue.
__________________