you should start a new thread on this, but generally speaking you will need to disconnect the lead from the cathode of the horz out tube, insert a amp meter (I like analog meters for this). Its a good idea to connect a .1uf cap across the leads when doing this as well. Often the sets will make it easy for you by providing a jumper that can be disconnected allowing connection to the jumper terminals.
|