Quote:
Originally Posted by VintagePC
Hmm... it might well be an inaccessible direct connection between the coils in the yoke itself.
|
The connection is most always inside the yoke housing.
Quote:
|
If that's the case, the best you can do for steps 2/3 is test across the yellow arrows. the result can indicate if coils are open.
|
Yep, but he's gotta disconnect one end, either the ground end as you suggested, or the top end. Doesn't matter which. While it's disconnected is a good time to also check continuity of the secondary winding of the transformer.
To the OP (original poster): is the capacitor across that winding (shown with dotted lines) actually in the set? If so, have you replaced it and/or verified that it's not shorted?
oc