View Single Post
  #11  
Old 06-21-2011, 03:55 PM
old_coot88 old_coot88 is offline
VideoKarma Member
 
Join Date: Sep 2009
Posts: 2,646
Quote:
Originally Posted by vts1134 View Post
Shorted to ground? It doesn't read shorted. I don't have a capacitor tester so I can only test if it's shorted.
You're using the highest ohms scale, and it's reading open circuit, right?
Quote:
R95 is actually reading around 3.6 ohms which is right at 20%. Possibly this should be changed but could that little fluctuation in tolerance possibly be the entire cause of the problem?
No, not a chance.

Last edited by old_coot88; 06-21-2011 at 04:03 PM.
Reply With Quote