replaced a couple in the vert, no joy, need to get the right cap (.035) for the final one. I did replace the .0082 1kv and the .1 that is connected from the boost to the 390v b+. Nothing.
I scoped the PS B+ the ripple was right on the nose about 1v pp riding on the 400v. there is of course some horz but it was very small and the sams showed it (I assume since it was a fat line on the sams).
For fun I scoped the output from the sync sep. looked normal (no excessive horz noise) and also looked at the vert out grid, again nothing odd. the pairing is very subtle and comes and goes. it is not always adjustable out iwth the vert hold in fact I am not real sure the vert hold is really taking it out when it does work, but maybe its just resolving as I adjust.
I checked the yoke for leakage, even went so far as to sub the yoke, again nothing. I have the .035 cap but its an odd ball fit so I plan to just order the correct one. I also was stunned to find I did not have a 47uf axial lead cap (the cathod bypass cap).
|