Quote: "I replaced the screen resistor a while back, and if I run the set with the plate lead removed the screen resistor will lightly smoke(it gets hot otherwise). The plate lead of the damper is at B+ regardless of the screen voltage."
That shouldn't be happening in this situation. You have other 6JE6's to sub?
As miniman82 suggested about the coupling cap also see if there's any voltage on the grid pin with the tube out.
|