I've got some readings on the electrolytics and a better picture of the schematic.

There are 5 multi stage electrolytic capacitors in the set. Towards the top of the picture, just above, and just to the right of the vertical centering control you can see two sections of C116. The negative on this cap reads shorted to ground which according to the schematic is correct. The other four caps are isolated from ground. Coming right off the center tap of the power transformer is the negative leads of C127, C128, and C131. Further along the line you have C132. Rather than give it away, how would I read the schematic and figure out what resistance reading those four caps should have to ground?