The CRT heater already has its own dedicated 'floating' winding in the power xfmr, designated 'Y and YZ', going to 'KIN' (for kinescope, the archaic term for CRT).
Try this- unplug the CRT from the socket and check for heater to cathode short with the ohmeter on highest range. It should read infinity (although a short might occur when the heater warms up). Also check DC resistance form the floating winding to ground. It should also read infinity, but double check the schematic to verify this, and that it's not connected to B+.
With the set on (and the CRT reconnected), measure the DC voltage between heater and ground, and see if it reads the same as the cathode (or not). Ideally, it should not if it's truly 'floating'. Then try shunting the heater to ground with the 10mf cap, first from one side of the heater and then the other. And see if the bar remains.