Quote:
Originally Posted by tubesrule
Nice catch Pete.
From the article it sounds like it was a certain monochrome set that had trouble with the burst being in the sync area, not the CPA set. I'm also getting out of this article that they changed the burst to ride on the black pedestal for NTSC not for the initial CPA. I guess it's easy enough to just make this switchable in the converter
Darryl
|
Darryl,
The only reason I can think of for putting the burst in the sync region is to prevent it being visible during retrace on some existing receivers without power blanking. But that also means that most existing receivers will see it as a second H sync pulse. I think it's an excellent idea to make this switchable so we can see the effects of one case or the other on the sets at ETF.