Quote:
Originally Posted by miniman82
I like the CTC-4 method myself, where you displace the lines a little to make sure they are straight, then bring them back together with the neck magnets. To each their own.
|
This is especially helpful in early sets, where the dynamic convergence was AC coupled, meaning it affected the center and both edges, but left the half-way points alone. Later sets used diodes or some such in the convergence circuit to force the center to stand still when the dynamics were adjusted.
If you have the Pict-O-Guide for your vintage of set, following that should get you there.