View Single Post
  #11  
Old 05-17-2012, 06:40 PM
N2IXK's Avatar
N2IXK N2IXK is offline
Technohippie
 
Join Date: Apr 2011
Location: Sittin' on the "Group W" bench...
Posts: 816
Quote:
Originally Posted by Magnavox300 View Post
Just curious, can you double the capacitance value on a electrolytic?
I needed a 5uf, but I bought a 10uf since I couldn't find a 5.
In most cases, doubling the capacitance will not cause any problems. Possible exceptions:

Filter caps right off the cathode of a rectifier tube. Using a grossly oversize cap here can overtax the rectifier tube due to excessive charging current. Tube manuals usually specify a maximum capacitance value for each tube type and filter arrangement.

Caps used in timing circuits.

Capacitors used in loudspeaker crossover networks.

Electrolytic capacitors in general have pretty lousy tolerance specs. -20%/+100% was typical for tube era caps

Exact tube era values can be a bit hard to find these days. instead of 20, 30, 50 uF, today 22, 33, 47 are the usual nominal values.