Phil:
Agree that nothing seems out of range. 33K vs 39K will only affect vert hold range. It locks OK.
The vertical output transformer could have some shorted primary. Check resistance with a DC meter, not a digital one. Some digital meters are fooled by high inductances because they use an AC voltage for resistance.
Make sure the 100K 1W is not burned. It may be necessary to sub a VOT for test. You can try driving the output stage with about 20 VAC, 60Hz to see if it will sweep at all. It will be distorted, but it will give an indication.
|