Quote:
Originally Posted by DaveWM
where exactly is the arcing? you really want to avoid that.
I cant see enough of the schematic, but need to know where R135 goes.
some sets tie in the video signal from the video out tube into grid of the shunt. This is done for more rapid adjustment of HV.
|
looks like r135 1.5 meg goes from grid of reg tube to hv adjust pot and horiz lin. c99 cap was changed its a .00
33 ceramic. the meter i used i know now that it has 5ma increments so the amount it moved i think its safe to say that i got .5 and 1.5 ma because it never got near the 5ma line.