Thread: Low B+ Voltage
View Single Post
  #2  
Old 01-13-2013, 03:13 PM
maxhifi's Avatar
maxhifi maxhifi is offline
VideoKarma Member
 
Join Date: Dec 2010
Posts: 1,869
1. Measure the +275V test point, and make sure it is close to 275V

2. Measure R185B and R186C out of circuit, and make sure they're within 20% of spec

3. Have C223A and C224B been replaced? I wouldn't really trust a 60+ year old electrolytic capacitor which hasn't been used in 40 years.

4. If all of above is good, it means there's excess load on the +135V supply.... figure out why.