Hi All;
Since I have taken out all my Electrolytics on my 630, I can speak to this.. And the answer is that there are "two" caps that are Isolated from Ground, on top.. C220 and C222 and "two" that are underneath the cabinette.. C221 and C225.. All four of these are not connected to ground, but If I remember correctly there is a Ground connection to one of the caps, for a reverse polarity.. The can is positive (in comparison to the other caps).. I would recheck all wiring against schematic, make a copy of your schematic on another paper(s) and as each wire is checked, draw thru it with a marker, your choice of color.. I prefer yellow markers, but blue also works..
THANK YOU Marty

Last edited by Geist; 01-25-2013 at 12:32 PM.