Thread: Rca ctc-5
View Single Post
  #184  
Old 02-04-2013, 12:46 PM
old_tv_nut's Avatar
old_tv_nut old_tv_nut is offline
See yourself on Color TV!
 
Join Date: Jul 2004
Location: Rancho Sahuarita
Posts: 7,757
I assume with the vectorscope you are using a gated rainbow pattern producing a "flower petal" vector display.

If the drives required for the red and blue guns were equal to make white, then the pattern would need to be elliptical, with the B-Y gain = 2.03/1.14 = 1.78 times the R-Y gain. (These are the ratios dividing the B-Y and R-Y axes before the chroma is modulated.) However, the red phosphor in the early tubes is weaker by about the same ratio, so equal (approximately) is correct (that is, the pattern is circular).

By a fluke of changing both the green and red phosphors in later tubes, the red gun requires less drive to make white; so there was a fix to reduce the red luminance drive; and at the same time, the yellower green sulfide phosphor means that the extra R-Y drive is still needed, to approximately compensate by making the difference between reddish and greenish colors greater. So, the matrix adjustment does not have to change, and can stay with a circular pattern when a new CRT (e.g., 21FBP22) is substituted.
Reply With Quote