View Single Post
  #8  
Old 02-11-2013, 09:34 AM
vts1134's Avatar
vts1134 vts1134 is offline
Looking For Time
 
Join Date: Apr 2011
Location: Pittsburgh, PA
Posts: 1,534
Quote:
Originally Posted by old_coot88 View Post
Yikes! NO, nein, nyet! Not until alignment is absolutely determined to be the cause of the problem. Undertaking a video IF alignment requires a sweep generator and scope, and a thorough understanding of the procedure.
Relax, I don't do alignments on my own . I am not yet at that level of skill and I know it. There is a local shop that I take the set to and he walks me through every step of the way. The last set I did I wouldn't have thought it needed alignment, but I was shocked how much better the picture looked afterwards. The alignment will be the last step on this set. I have to have everything else nailed down tight first.

Quote:
Originally Posted by Eric H View Post
It has a loose connection somewhere, possibly in that repaired Ion Trap.
It could also be a flaky connection at a tube socket.
You need to start poking around with a wood or plastic stick and see if you can isolate it.

Bad Mica caps in the sweep circuit are also a possibility but I wouldn't think tapping would affect them much.
I'll get tapping as soon as I can .

Quote:
Originally Posted by old_coot88 View Post
From your account and from the video, the first thought is a H-K (heater-cathode) short in the CRT. Does the CRT heater have a dedicated 'floating' 6V winding, or does it run off the main heater supply?
It runs from the main heater supply. One thing I don't quite understand is the schematic looks like the heater and cathode are tied together. Wouldn't that would mean the heater and cathode are constantly shorted? What am I missing?

Reply With Quote