did a little more cleaning, replaced the broken power diode, checked the plug resistance 150 ohms? oh yea the thermal switch. The B+ was about 10k thats good and it started out at about 3K so the filter caps don't seem to be shorted.
So next up will be the jump the thermal B+ AND jump the heater since I will be using a variac. Monitor the B+ and see how she goes.
Almost all of the tubes were heavy with corrosion on the pins, I used a wire brush and contact cleaner. I will prob have to work over the tube sockets as well with the dental brushes and cleaner.
The vert out looks like it was chewed on by something at one point, but I have a NOS one of those, same with the horz eff coil, but also have a backup.
The G1 and G2 pots are hidden behind a bolted on cover (nice) and were mostly frozen. again cleaner and lube seems to have gotten them going, but I may replace them all, I hate crappy pots, and I dont think they are anything special.
|