Quote:
Originally Posted by DaveWM
Seems the issues would be working with the very fine gauge wire needed to get the number of turns up to the working voltage AND having to deal with insulation to prevent arc over between windings.
|
These are the least of your worries- it's striking a balance between inductance, the resistance of the winding, and distributed capacitance. These influence the resonant frequency of the whole transformer, get it wrong and all your work will be for nothing. Never mind the fact that you need the special winding rig...