no metal shield over the chroma on this one. I just found another shorted cap across the shunt tube (.0033), that will booger up the HV regulation some.
its coming along, I will prob try it again after I replace that .1 in the grid of the video out. I just don't want to smoke any plate load resistors due to tubes cooking off with bad coupling caps. I got a couple more easy ones out of the way on the chassis bottom, some more .1's
You can see the fine cracks in the epoxy dip of a lot of the brown drops.
|