Arcing to external points takes a while to pose a threat, but don't let it go too long. Internal to internal arcing is usually harder to notice let alone cure and tends to mean the fly is on it's way out. If internal to internal arcing takes a path outside the fly (ie. you see a spark jump from one winding to another through the air) then that may be curable by recoating the fly, and should be done right after the condition is noticed to prevent damage.
|