View Single Post
  #7  
Old 08-16-2013, 09:35 PM
Eric H's Avatar
Eric H Eric H is offline
Administrator
 
Join Date: Jun 2002
Location: So. Calif
Posts: 11,565
Are these the caps (photo below?)

I resoldered the transistors on the Horiz board to try to cure the intermittent, it seemed to have worked but very shortly after turning it back on I started to hear some HV arcing and shortly it was shooting fire out the bottom of the tripler, hopefully it's not a runaway HV problem but I will need to replace those caps and the tripler before I try it again.

Rechecked the CRT and it's still fine.

Possibly the Tripler was what took this set out of service originally, I don't think that inch long crack happened instantly.
The intermittent connection may have come later, maybe when I fixed that it brought the HV up enough for the Tripler to start leaking again?

Will a 212-148-01 Tripler replace a 212 141 05? Turns out he one I have is totally wrong for this model so I will have to find another one.
Attached Images
File Type: jpg CCIIlabel.jpg (12.0 KB, 10 views)
File Type: jpg tripler.jpg (13.4 KB, 30 views)
File Type: jpg CCIIcaps.jpg (16.0 KB, 42 views)
Reply With Quote