Quote:
Originally Posted by TinCanAlley
Those voltages test out as 248VDC and 761VDC. So their not on the low side.
I was hoping someone could look over the schematics I posted earlier and tell me what happens when the setup switch is activated. To me, a beginner, it looks like it does something and collapses the vertical. That's my best guess based on what I get looking over the schematics. If that's what's happening, then the lack of setup line for all but a faint blue is puzzling.
If it comes down to replacing the FB or yoke, I'll live with the bars. I don't want to get that involved. I think for the heck of it I'll look over all the caps and resistors in the 750V boost area. Could be a decoupling cap.
|
Service switch kills vertical also kills video & gives the 3 video outs a
constant voltage. On this chassis it also adds a crude blanking pulse.
If all the DC voltages are correct you should get very bright service
lines. At that point its 99% the CRT. Sometimes the CRT can look
& test good but be a little weak.
Good news ! Since I was a bench man & only did about 25 of these
sets I ran it by our old road man over a beer. He did a repair on
one once & it had the exact same jailbars. Bad news is the set was
very old & they didnt want to pay to pull the chassis. At least you
know this wasnt self induced & a real failure, possably common.
Just for kicks remove the wire from service switch that go to
jcn of R295 & R297. See if they go away.
73 Zeno