Quote:
Originally Posted by Reece
Yes, one lug is one side of the cap and goes to ground. Another lug is the other side of the cap and goes to the screen of the first 24 tube, ... Should be able to trace this out.
|
That's essentially what I was trying to say (being a EE I may forget what it was like before I learned this stuff). And he should set his DVM to the low ohms range, say below 200 ohms. So it reads as an open if he gets on the wrong side of the resistor. Or he should look for either a 0 ohm reading, or a reading of 250 ohms.