Well the new 12BY7 helped a little but it still has the ghost issue and a smearing in white from the ghosting almost looks like ice in the white objects , the ghosting doesn't change when the tuner is adjusted but the smear caused by the ghost changes when tuned back too far and the color wont work ( pictures are to show ghosts and the smear and the changing of the smear ) get no color i , I jumped the delay line and saw no change or no effect , I guess you have to disconnect one end , I accidently disconnected the ground to the delay line , things looked odd and there was no brightness control , I found the cause of the bright green line when in service mode - too much kine bias.
I also checked the hot cathode with a .47 cap hooked to each end of the meter wires, I see 190 ma