View Single Post
  #5  
Old 04-07-2014, 03:35 PM
DavGoodlin's Avatar
DavGoodlin DavGoodlin is offline
Motorola Minion
 
Join Date: Aug 2011
Location: near Strasburg PA
Posts: 3,504
I use a B&K 445 for testing monochrome CRTs, it seems to predict a good picture consistently, but I disconnected the rejuvenate (dynamic intensifier) button due to its brute-force method.

Before I got the B&K, I always used my Heathkit IT-5320 to rejuvenate and never had a problem but it is not the most accurate tester.
The Heathkit limits current (and potential damage) using incandescent S-7 120v lamps and has a clean function that is much milder than the Rejuvenate.

For both "restore" functions, you start out with a cold filament and ramp it up slowly until a steady current is drawn. It takes practice, but with a CR70, rejuvenation is much more foolproof, hence the value.
__________________
"When resistors increase in value, they're worthless"
-Dave G
Reply With Quote