View Single Post
  #7  
Old 06-23-2014, 04:07 PM
dtvmcdonald's Avatar
dtvmcdonald dtvmcdonald is offline
VideoKarma Member
 
Join Date: Nov 2012
Posts: 1,268
It has had a loving owner all these decades, as indicated by the way the ETF got it (gift from an estate ... the money I pay goes to the ETF.) McVoy has looked at
the bottom and its not recapped, at least not mostly. Mouser has every single
electrolytic or film cap needed, except one HV film cap I luckily have left
over from the recent Emerson 7" electrostatic recap, and a 1000 uF 6 volt
nonpolar that McVoy says never goes bad, and for which I also, amazingly,
have two 2000 uF 25 volt ones that will work (back to back).

This affair will take time and more time.

I did notice one thing ... the RCA manual gives the tolerances for most
electrolytics as -10 +20, +50, +100, or +250%. Since modern electrolytics
are +-20%, I bought larger value ones so their value lies within
the specified range. A look at the schematic shows why the RCA engineers
picked the + tolerance they did. For the films I ordered +-5%, for pennies more.

Last edited by dtvmcdonald; 06-23-2014 at 04:13 PM.
Reply With Quote