Yes, pulling the 6BG6 will prevent the HV from coming up.
I wouldn't suggest just disconnecting the plate cap on one, though. That leaves the screen grid voltage on the tube, and screen voltage without plate voltage applied can result in excessive screen dissipation, damaging the tube or burning the screen resistor.
|