In the damper circuit, the doide is suppose to stop oscillations in the flyback after
the conduction pulse turns off the hv output tube.... So I would say your problem
lays in the damper circuit, possibly a cap in the cathode to ground area.... Or the tube
itself.... ? Odd I would think oscillations in something near the horiz deflection circuit
would effect the linearity of the lines.... But it seems to effect the brightness of the
lines.... Maybe the problem lay off the damper circuit feeding the blanking circuit....?

I'm sure you'll get it.... Looks like a good picture otherwise.... Wonder what happened to
that Toad soap....? I can't believe it didn't catch on....

.