Originally Posted by zeno View Post
OK this is from the G line manual.
It calls for a 95-3172-01 so may be different.

primary grey & grey brown 3.3 ohm
sec #1 black & black green 8.8 ohm for DGS
sec #2 blue & yellow filament 6.3 V 840ma
sec #3 white & black yellow 3.5mfd cap only
red yellow tap to ground
red black 135V
green 35V
green 35V
brown 6V
red 135V

73 Zeno
My Zenith tranny listing shows the -01 to have UL mods, probably the beefier insulation when they changed the UL requirements in 77/78. Zenith microfiche also shows the -01 mod to be the only orderable part - the orig tranny is subbed by the -01. Also, some trannys had the suffix rubber stamped in silver or gray paint after the stamped-in-steel part number.