View Single Post
  #17  
Old 04-13-2015, 04:09 PM
NoPegs's Avatar
NoPegs NoPegs is offline
The glass is -3dB.
 
Join Date: Mar 2014
Location: Amish Country PA.
Posts: 376
Quote:
Originally Posted by bandersen View Post
I haven't measured it but just going my the filament brilliance it's more than I ever do manually.

Yes, I have used the auto and manual restore/rejuv functions on a Predicta and it didn't blow out the filament. I suspect it's going a certain % higher than the filament voltage setting.

Not sure if a LM317 would work since although it's DC it's not filtered.
I'll investigate this further via an actual lash-up possibly this weekend. My initial hypothesis is that the LM317/350/338 will just act as a peak-clipper. I also forgot to consider that the duty cycle is going to be something around 33% instead of 100%, so that helps the TDP side of things. Hell, it might be entirely possible that just a diode and a regulator will let you run strings as low as 35v off mains. I'm also curious to see how it affects the initial warmup. It might actually take longer than a thermistor, because the hard maximum is 595mA in the example I gave. I intend to find out for us all.
Reply With Quote